iFactory.Godot/Mods/工业数据采集与分析应用分享/Scripts/温湿度Reader.cs

153 lines
3.5 KiB
C#

using Godot;
using System;
using System.Collections.Generic;
using System.Globalization;
using System.Net.Mime;
using System.Runtime.InteropServices;
using System.Threading;
using System.Timers;
using BITKit;
using Cysharp.Threading.Tasks;
using SharpModbus;
using Timer = System.Timers.Timer;
namespace BITFactory;
public partial class 湿Reader : Node
{
[ExportCategory("参数")]
[Export(PropertyHint.Range,"100,2000")] private int interval=500;
[ExportCategory("网络设置")]
[Export] private string ip="192.168.3.7";
[Export] private int port=502;
[ExportCategory("运行时")]
[Export]public double humidity = 50.0;
[Export]public double temperature = 26.0;
[ExportCategory("UI 绑定")]
[Export] private UXContainer temperatureContaier;
[Export] private UXContainer humidityContainer;
[Export] private LineEdit ipEdit;
[Export] private LineEdit portEdit;
[Export] private RichTextLabel hintsLabel;
private ModbusMaster _modbus;
private System.Timers.Timer timer;
private CancellationTokenSource _CancellationTokenSource;
public override void _Ready()
{
_CancellationTokenSource = new CancellationTokenSource();
try
{
_modbus = ModbusMaster.TCP(ip, port);
}
catch (Exception e)
{
hintsLabel.Text = e.Message;
}
if (ipEdit is not null)
{
ipEdit.TextChanged += s => ip = s;
ipEdit.TextSubmitted +=s=> UpdatePortAndIP();
}
if(portEdit is not null)
{
portEdit.TextSubmitted += OnPortChanged;
void OnPortChanged(string s)
{
UpdatePortAndIP();
if (int.TryParse(s,out var newPort))
{
}
else
{
portEdit.Text=string.Empty;
portEdit.PlaceholderText = "请输入正确的端口号";
}
}
}
UpdatePortAndIP();
timer = new Timer();
timer.Interval = interval;
timer.Elapsed += OnTimerElapsed;
timer.AutoReset = false;
timer.Start();
}
public override void _ExitTree()
{
_CancellationTokenSource.Cancel();
timer.Stop();
}
/// <summary>
/// 内部方法,用于更新IP和端口
/// </summary>
private void UpdatePortAndIP()
{
_modbus?.Dispose();
try
{
_modbus = ModbusMaster.TCP(ip, port);
}
catch (Exception e)
{
BIT4Log.Log<湿Reader>(e.Message);
}
}
/// <summary>
/// 内部方法,定时器回调用于读取Modbus
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
private async void OnTimerElapsed(object sender, ElapsedEventArgs e)
{
await UniTask.SwitchToTaskPool();
try
{
_CancellationTokenSource.Token.ThrowIfCancellationRequested();
hintsLabel.SetTextAsync( "正在读取温湿度数据..."+DateTime.Now);
var vs = _modbus.ReadInputRegisters(1, 0, 2);
_CancellationTokenSource.Token.ThrowIfCancellationRequested();
hintsLabel.SetTextAsync( "已采集到数据,正在解析..."+DateTime.Now);
if (vs is not { Length: 2 })
{
hintsLabel.SetTextAsync(hintsLabel.Text = $"获取温湿度数据失败:数据长度为:{vs.Length}"+DateTime.Now);
return;
}
temperature = vs[0] / 10.0;
humidity = vs[1] / 10.0;
hintsLabel.SetTextAsync("已获取到温湿度数据:"+DateTime.Now);
temperatureContaier.label.SetTextAsync(temperature.ToString(CultureInfo.InvariantCulture)); ;
humidityContainer.label.SetTextAsync(humidity.ToString(CultureInfo.InvariantCulture));
timer.Start();
}
catch (OperationCanceledException)
{
BIT4Log.Log<湿Reader>($"Modbus读取任务已取消");
}
catch (Exception ex)
{
hintsLabel.SetTextAsync(ex.Message);
timer.Start();
}
}
}